TRAINING ELECTRICAL INSTALLATION IN HAZARDOUS AREA DI JAKARTA

TRAINING INSTALASI LISTRIK DI DAERAH BERBAHAYA DI JAKARTA

TRAINING IGNITION BY HOT SURFACES DI JAKARTA

pelatihan ELECTRICAL INSTALLATION IN HAZARDOUS AREA di jakarta

COURSE CONTENT

Explosive Atmosphere, origin and characteristic values
* Evaporation
* Convection, diffusion density ratio
* Flash point and combustion point
* Classification of flammable liquids into danger classes
* Explosive mixture of dust and air
* Exothermic chemical reaction and its characteristic values
* Ignition sources and their characteristic values
* Ignition flame
* Influence of electrical values
* Ex-groups, maximum experimental safe gap
* Ignition by hot surfaces

Regulation and Specifications
* Regulations concerning electrical installations in explosive atmosphere
* Definitions
* Potentially explosive atmosphere, electrical apparatus in acetylene plants
* IEC works

Type of Protection
* General, opening apparatus, terminals, cable and conduct entries
* Oil immersed equipments
* Pressurized appartus
* Flameproof enclosure

Intrinsic safety
* General specific constructional requirements
* Installation requirements for intrinsically safe circuits
* Tests

Planning, installation and operation of electrical systems in potentially explosive atmospheres
* Assessment of possible explosion risk
* Planning electrical installations for use in potentially explosive atmosphere
* Selection of apparatus
* Measuring and control equipment
* Lighting systems

Operation of electrical equipment in potentially explosive atmosphere
* General
* Operations of electrical equipment
* Instruction of persons
* Repair of explosion-protected electrical apparatus
* Repair work not affecting the explosion protection

Switchgear for use in potentially explosive atmospheres
* Terminals
* Protection against dust and wear,
* Types of protection for electrical switchgear

Lamps and Luminaires
* General, incandescent lamps, discharge lamps, high pressure mercury lamps
* Safety luminaires, portable lights, flameproof luminaires
* Pressurized luminaires

WHO SHOULD ATTEND

Managers involved with energy management, Electrical engineers and Technical Staff who have to deal with the aspect of electrical and industrial power system protection, control and operation.

INSTRUCTOR
Ir. Qamaruzzaman, MT graduated from Electrical Engineering, Bandung Institute Technology. He studied at Technische Universitaet Braunschweig, Federal Republic of Germany in 1979 to add has knowledge. He has been lectures and researcher at Department of Electrical Eng ITB since 1973. He has experience in PT. Sucofindo as senior Engineer for Perum Pelabuhan II Project, as senior Engineer, Feasibility study at PT. Spektra, etc. He is actives in IEEE Society Power Electronic, Industrial Engineer, ndustrial Application sine 1986.

Lokasi Pelatihan Tahun 2021 :

Yogyakarta, Hotel Dafam Seturan

Jakarta, Hotel Amaris La Codefin Kemang

Bandung, Hotel Grand Serela Setiabudhi

Bali, Hotel Ibis Kuta

Lombok, Hotel Jayakarta

Catatan :

  • Waktu pelatihan Dua+1* hari dengan Biaya tersedia untuk Perorangan, Group, dan Inhouse Training, belum termasuk akomodasi/penginapan.
  • Untuk biaya dan jadwal training harap menghubungi marketing kembali

Investasi training:

Investasi pelatihan selama dua hari tersebut menyesuaikan dengan jumlah peserta (on call). *Please feel free to contact us.

Apabila perusahaan membutuhkan paket in house training, anggaran investasi pelatihan dapat menyesuaikan dengan anggaran perusahaan.

Fasilitas training:

Free Penjemputan dari bandara ke hotel*.

Modul / Handout.

Flashdisk*.

Certificate of attendance.

FREE Bag or bagpacker.

Training Kit (Photo Documentation, Blocknote, ATK, etc).

2x Coffe Break & 1 Lunch.

Souvenir .